NSN: 5925-00-018-9709

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.140 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Arc Quenching Method

    air

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • External Actuator Linkage Arrangement

    one and two linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 0.500 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    6.500 ounces

  • Terminal Type And Quantity

    4 threaded stud

  • Body Width

    1.500 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...