NSN: 5925-00-021-6513

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Precious Material

    silver

  • Precious Material And Location

    contact surfaces silver

  • Nominal Thread Size

    0.375 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Position Designation

    between pole one and two

  • Trip Release Method

    magnetic-hydraulic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Thread Quantity Per Inch

    32

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Case Material

    metal

  • Body Width

    1.281 inches maximum

  • Bushing Length

    0.365 inches minimum and 0.390 inches maximum

  • Specification/standard Data

    81349-mil-c-39019/3 government specification

  • Terminal Type And Quantity

    4 wire hook

  • Test Data Document

    81349-mil-c-39019 specification

  • Unpackaged Unit Weight

    3.400 ounces

  • Frequency In Hertz

    400.0

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed and moisture resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 0.600 maximum at 200 pct

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum and 7.000 maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Style

    multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...