NSN: 5925-00-021-6970

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    3 wire hook

  • Pole Quantity

    2

  • Reset Method

    manual

  • Frequency In Hertz

    400.0 first location

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Body Length

    1.464 inches minimum and 1.526 inches maximum

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc second location

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Bushing Length

    0.360 inches minimum and 0.380 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Precious Material And Location

    contact surfaces silver

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 3.000 maximum at 200 pct all locations

  • Mounting Surface To Terminal End Distance

    1.647 inches minimum and 1.709 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac first location

  • Body Width

    1.841 inches minimum and 1.906 inches maximum

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Width

    0.620 inches minimum and 0.630 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches minimum and 0.906 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac first location

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...