NSN: 5925-00-042-7805

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Switch Function And Quantity

    1 control

  • Switch Location And Position Designation

    internal at pole one

  • Body Length

    1.622 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Trip Release Characteristic

    instantaneous single location

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Body Width

    0.625 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Bushing Length

    0.380 inches nominal

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Frequency In Hertz

    60.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Style

    single pole type

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Ultimate Trip Time Per Pole In Seconds

    0.005 nominal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Mounting Surface To Terminal End Distance

    1.656 inches nominal

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...