NSN: 5925-00-045-6925

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 clip

  • Thread Series Designator

    unf

  • Adjustable Trip Setting Current Range Per Pole In Amps

    p125.0/p350.0 ac and p125.0/p350.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac and 10000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac and 25.0 amperes dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.188 inches nominal

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    3.688 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.313 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.938 inches nominal

  • Case Material

    plastic

  • Frequency In Hertz

    400.0

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct and 15.000 maximum at 200 pct

  • Nominal Thread Size

    0.190 inches

  • Actuator Position Designation

    at pole two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    instantaneouss and time delay

  • Trip Release Method

    thermal-magnetic

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac and 250.0 dc

  • Features Provided

    adjustable trip release

  • Special Handling Feature

    magnetic

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Body Height

    4.125 inches nominal

  • Body Width

    4.125 inches nominal

  • Body Length

    6.509 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...