NSN: 5925-00-055-9352

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.380 inches maximum

  • Inclosure Protection Type For Which Designed

    vibrationproof and hermetically sealed

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Internal Trip Release Configuration

    shunt trip single location

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    2.200 ounces

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Body Length

    1.500 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Body Width

    0.625 inches nominal

  • Special Handling Feature

    magnetic

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 0.600 maximum at 200 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...