NSN: 5925-00-068-0610
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Test Data Document05869-711598 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.0 amperes ac second location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Body Width1.490 inches minimum and 1.510 inches maximum 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Switch Location And Position Designationinternal at each pole 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Unpackaged Unit Weight0.438 pounds 
- 
                                    Mounting Surface To Terminal End Distance2.480 inches maximum 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Boss Height0.110 inches minimum and 0.130 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac first location 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Pole Quantity2 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Auxiliary Switch Function And Quantity2 control 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Switch Current Rating And Type In Amps5.0 ac and 1.0 dc 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Switch Voltage Rating And Type In Volts125.0 ac and 50.0 dc 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.930 inches minimum and 1.950 inches maximum 