NSN: 5925-00-109-1753
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Overall Length
2.000 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
 - 
                                    
Case Material
plastic
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 single location
 - 
                                    
Pole Quantity
1
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.570 inches nominal
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Terminal Type And Quantity
2 screw
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Reset Method
manual
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc single location
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Actuator Function
reset
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
250.000 minimum at 125 pct single location and 30.000 maximum at 200 pct single location
 - 
                                    
Body Width
1.188 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
1.188 inches nominal
 - 
                                    
Body Style
single pole type
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Internal Trip Release Configuration
series trip single location
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    