NSN: 5925-00-132-2207

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Iii Unpackaged Unit Weight

    3.700 ounces

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Boss Height

    0.150 inches nominal

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    12a single pole type

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Pole Quantity

    1

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3.000 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.800 minimum at 200 pct and 11.000 maximum at 200 pct single location

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.