NSN: 5925-00-147-0748

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Thread Quantity Per Inch

    32

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.828 inches minimum and 1.860 inches maximum

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Case Material

    plastic

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 threaded stud

  • Unpackaged Unit Weight

    4.750 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.200 maximum at 200 pct

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc

  • Storage Type

    unimproved open

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.924 inches minimum and 1.952 inches maximum

  • Body Width

    0.738 inches minimum and 0.750 inches maximum

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.