NSN: 5925-00-279-2925
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Mounting Facility Type And Quantity
2 unthreaded hole
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc single location
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Body Width
1.250 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 push button
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Mounting Surface To Terminal End Distance
1.266 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.250 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches nominal
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Inclosure Protection Type For Which Designed
weatherproof
 - 
                                    
Body Style
single pole type
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 nominal at 200 pct single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.906 inches nominal
 - 
                                    
Terminal Type And Quantity
2 tab w/screw
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 dc single location
 - 
                                    
Overall Length
2.000 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    