NSN: 5925-00-359-4001

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Contact Arrangement

    single pole, double throw

  • Bushing Length

    0.375 inches maximum

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Body Width

    1.937 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.007 minimum at 150 pct all locations and 0.030 maximum at 200 pct all locations

  • Body Length

    1.562 inches maximum

  • Switch Location And Position Designation

    internal at each pole

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches nominal

  • Switch Current Rating And Type In Amps

    0.5 dc

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Terminal Type And Quantity

    6 wire hook

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    3 alarm

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc third location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...