Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac single location
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.045 inches minimum and 2.075 inches maximum
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Internal Trip Release Configuration
relay trip single location
 - 
                                    
Mounting Surface To Terminal End Distance
2.830 inches maximum
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Body Width
0.760 inches maximum
 - 
                                    
Body Length
2.530 inches maximum
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.630 inches minimum and 0.660 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
 - 
                                    
Boss Height
0.125 inches minimum and 0.155 inches maximum
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Circuit Protection Type
overvoltage single location
 - 
                                    
Body Style
single pole type
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Thread Pitch Diameters
+0.1177/+0.1214 inches
 - 
                                    
Trip Release Characteristic
instantaneous single location
 - 
                                    
Special Features
rated relay coil voltage 24 vdc
 - 
                                    
Terminal Type And Quantity
4 threaded stud
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Manufacturers
    