NSN: 5925-00-430-9168
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Width0.625 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Maximum Continuous Load Current Rating Per Pole5.0 amperes ac 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Body Stylesingle pole type 
- 
                                    Bushing Length0.375 inches nominal 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Case Materialmetal 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Time Per Pole In Seconds5.000 minimum and 30.000 maximum 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.900 minimum at 200 pct and 4.000 maximum at 200 pct and 0.006 minimum at 500 pct and 0.030 maximum at 500 pct 
- 
                                    Inclosure Protection Type For Which Designedmoisture resistant and dustproof and shockproof and vibrationproof and explosion resistant 
- 
                                    Frequency In Hertz400.0 
- 
                                    Terminal Type And Quantity2 wire hook 
- 
                                    Mounting Surface To Terminal End Distance1.700 inches maximum 
- 
                                    Mounting Facility Type And Quantitythd bushing w/panel seal 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps300.0 ac 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Thread Series Designatorunef 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    


