Technical Characteristics
- 
                                    Bushing Length0.380 inches maximum 
- 
                                    Special Featurespole 2 time delay 4.0 to 25.0 seconds ta 200 pct of rated load 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Switch Voltage Rating And Type In Volts120.0 ac and 50.0 dc 
- 
                                    Thread Series Designatorunef 
- 
                                    Body Width1.250 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Switch Current Rating And Type In Amps0.5 ac and 0.5 dc 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Maximum Continuous Load Current Rating Per Pole1.0 amperes ac second location 
- 
                                    Actuator Position Designationbetween pole one and two 
- 
                                    Body Length1.500 inches maximum 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Case Materialmetal 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Terminal Type And Quantity4 wire hook 
- 
                                    Inclosure Protection Type For Which Designedhermetically sealed 
- 
                                    Maximum Continuous Load Current Rating Per Pole300.0 milliamperes ac first location 
- 
                                    Mounting Surface To Terminal End Distance1.780 inches maximum 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Switch Location And Position Designationinternal at pole two 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Reset Methodmanual 
- 
                                    Pole Quantity2 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.300 minimum at 200 pct all locations and 2.000 maximum at 200 pct all locations 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    