NSN: 5925-00-450-8717
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Height2.677 inches minimum and 2.697 inches maximum 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Pole Quantity1 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 dc single location 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Body Width1.490 inches minimum and 1.510 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes dc single location 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Center To Center Distance Between Terminals Parallel To Length4.349 inches minimum and 4.369 inches maximum 
- 
                                    Body Stylesingle pole type 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.990 inches minimum and 1.010 inches maximum 
- 
                                    Body Length5.240 inches minimum and 5.260 inches maximum 
- 
                                    Unthreaded Mounting Hole Diameter0.190 inches nominal 
- 
                                    Trip Release Characteristicinstantaneous single location 
- 
                                    Terminal Type And Quantity2 compression 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts125.0 dc single location 
- 
                                    Case Materialplastic 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent120.0 single location 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.349 inches minimum and 4.369 inches maximum 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Boss Height0.208 inches minimum and 0.228 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Actuator Functiontrip-reset 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    