NSN: 5925-00-465-8310
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Mounting Surface To Terminal End Distance2.461 inches minimum and 2.481 inches maximum 
- 
                                    Pole Quantity2 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes ac 
- 
                                    Maximum Continuous Load Current Rating Per Pole22.0 amperes ac 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts125.0 ac 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2000.0 ac 
- 
                                    Circuit Protection Typeovercurrent 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Internal Trip Release Configurationseries trip 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current4.000 minimum at 200 pct and 10.000 maximum at 200 pct 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
- 
                                    Thread Series Designatorunc 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Trip Release Methodmagnetic-hydraulic 
- 
                                    Trip Release Characteristictime delay 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Reset Methodmanual 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Body Width1.490 inches minimum and 1.510 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.928 inches minimum and 1.948 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Boss Height0.130 inches minimum and 0.150 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat each pole 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Frequency In Hertz60.0 
- 
                                    Terminal Type And Quantity4 threaded stud 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    