NSN: 5925-00-476-8081
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Surface To Terminal End Distance2.461 inches minimum and 2.481 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.928 inches minimum and 1.948 inches maximum 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.052 inches minimum and 2.072 inches maximum 
- 
                                    Terminal Type And Quantity12 threaded stud 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Body Width4.490 inches minimum and 4.510 inches maximum 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent150.0 all locations 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and moisture resistant 
- 
                                    Main Contact Tripping Mechanism Typenontrip free 
- 
                                    Pole Quantity6 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes ac all locations 
- 
                                    Case Materialplastic 
- 
                                    Mounting Facility Type And Quantity12 threaded hole 
- 
                                    Boss Height0.130 inches minimum and 0.150 inches maximum 
- 
                                    Body Length2.490 inches minimum and 2.510 inches maximum 
- 
                                    Unpackaged Unit Weight1.750 pounds 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.300 minimum at 200 pct all locations and 0.900 maximum at 200 pct all locations 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    