NSN: 5925-00-478-7233
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Body Width4.125 inches nominal 
- 
                                    Reset Methodmanual 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Release Characteristicinstantaneous all locations and time delay all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.500 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.375 inches nominal 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Trip Release Methodthermal-magnetic all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Terminal Type And Quantity6 compression 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts60.0 ac all locations 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant and general purpose 
- 
                                    Case Materialplastic 
- 
                                    Body Height3.375 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length5.062 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.375 inches nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps14000.0 ac all locations 
- 
                                    Body Length6.000 inches nominal 
- 
                                    Unthreaded Mounting Hole Diameter0.188 inches nominal 
- 
                                    Boss Height0.125 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole30.0 amperes ac all locations 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current85.000 minimum at 200 pct all locations and 240.000 maximum at 200 pct all locations 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    