                                    Bushing Length0.250 inches nominal 
- 
                                    Maximum Continuous Load Current Rating Per Pole50.0 amperes ac single location and 50.0 amperes dc single location 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Actuator Functiontrip-reset 
- 
                                    ~1data on certain environmental and performance 
- 
                                    Terminal Type And Quantity2 screw 
- 
                                    Mounting Surface To Terminal End Distance1.812 inches maximum 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Trip Release Methodthermal single location 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Body Length1.094 inches maximum 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Pole Quantity1 
- 
                                    Case Materialmetal 
- 
                                    Inclosure Protection Type For Which Designedexplosion resistant and moisture resistant 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts115.0 ac single location and 28.0 dc single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.703 inches nominal 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3500.0 ac single location and 6000.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current2.000 minimum at 400 pct single location and 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location and 7.000 maximum at 400 pct single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent138.0 single location 
- 
                                    Body Width0.750 inches maximum 
- 
                                    Nominal Thread Size0.469 inches 
- 
                                    Thread Series Designatoruns 
- 
                                    Test Data Document81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type 