NSN: 5925-00-487-0196
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Body Width0.750 inches nominal 
- 
                                    Boss Height0.115 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole2.5 amperes ac single location 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Body Length2.300 inches maximum 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.200 minimum at 200 pct single location and 0.600 maximum at 200 pct single location 
- 
                                    Trip Release Methodmagnetic single location 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Thread Series Designatorunc 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac single location 
- 
                                    Reset Methodmanual 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac single location 
- 
                                    Unpackaged Unit Weight0.250 pounds 
- 
                                    Pole Quantity1 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Case Materialplastic 
- 
                                    Terminal Type And Quantity2 threaded stud 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Body Stylesingle pole type 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.680 inches nominal 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Inclosure Protection Type For Which Designedcorrosion resistant and fungus resistant 
- 
                                    Mounting Surface To Terminal End Distance2.510 inches nominal 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    


