NSN: 5925-00-495-6519
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 ac all locations 
- 
                                    Mounting Surface To Terminal End Distance2.480 inches nominal 
- 
                                    Manual Actuator Type And Quantity4 toggle 
- 
                                    Case Materialplastic 
- 
                                    Pole Quantity4 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.930 inches minimum and 1.950 inches maximum 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.740 inches minimum and 0.760 inches maximum 
- 
                                    Test Data Document18876-11156258 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Ultimate Trip Time Per Pole In Seconds100.000 minimum all locations and 400.000 maximum all locations 
- 
                                    Body Width3.060 inches nominal 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Boss Height0.150 inches nominal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current20.000 minimum at 200 pct all locations and 80.000 maximum at 200 pct all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Body Length2.530 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.050 inches minimum and 2.070 inches maximum 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Mounting Facility Type And Quantity8 threaded hole 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    External Actuator Linkage Arrangementone, two, three, and four linked 
- 
                                    Maximum Continuous Load Current Rating Per Pole50.0 amperes ac all locations and 50.0 amperes ac all locations and 50.0 amperes ac all locations and 100.0 milliamperes ac all locations 
- 
                                    Terminal Type And Quantity8 threaded stud 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    