NSN: 5925-00-498-1860
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Switch Terminal Typetab, solder lug 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.850 inches nominal 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.560 inches nominal 
- 
                                    Reset Methodmanual 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts120.0 ac all locations and 28.0 dc all locations 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Switch Contact Arrangementsingle pole, double throw 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Trip Release Ambient Temp Rating25.0 deg celsius nominal all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Switch Current Rating And Type In Amps7.0 ac and 4.0 dc 
- 
                                    Terminal Type And Quantity6 screw 
- 
                                    Body Length2.000 inches maximum 
- 
                                    Body Width0.850 inches maximum 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.841 inches nominal 
- 
                                    Auxiliary Switch Function And Quantity1 alarm 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Maximum Continuous Load Current Rating Per Pole4.0 amperes ac all locations and 4.0 amperes dc all locations 
- 
                                    Bushing Length0.280 inches maximum 
- 
                                    Nominal Thread Size0.469 inches 
- 
                                    Thread Series Designatoruns 
- 
                                    Case Materialplastic 
- 
                                    Trip Release Methodthermal all locations 
- 
                                    Switch Location And Position Designationinternal at pole three 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps2500.0 ac all locations and 2500.0 dc all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.341 inches nominal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent145.0 all locations 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Body Height2.765 inches nominal 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current4.000 minimum at 200 pct all locations and 35.000 maximum at 200 pct all locations 
- 
                                    Manual Actuator Type And Quantity1 push-pull 
- 
                                    Switch Voltage Rating And Type In Volts130.0 ac and 28.0 dc 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    