NSN: 5925-00-500-7026
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Terminal Type And Quantity2 tab w/screw 
- 
                                    Case Materialplastic 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent130.0 single location 
- 
                                    Thread Series Designatorunc 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length1.813 inches nominal 
- 
                                    Body Width0.750 inches nominal 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.234 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Manual Actuator Type And Quantity1 push button 
- 
                                    Mounting Facility Type And Quantity2 threaded hole 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Mounting Surface To Terminal End Distance1.344 inches nominal 
- 
                                    Overall Length2.172 inches nominal 
- 
                                    Pole Quantity1 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts110.0 ac single location and 30.0 dc single location 
- 
                                    Internal Trip Release Configurationseries trip single location 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current20.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Frequency In Hertz400.0 single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps3500.0 ac single location and 6000.0 dc single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Maximum Continuous Load Current Rating Per Pole6.0 amperes ac single location and 6.0 amperes dc single location 
- 
                                    Trip Release Methodmagnetic-hydraulic single location 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    