NSN: 5925-00-500-7889
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Overall Height24.125 inches nominal 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Body Stylerectangular dimensional envelope 
- 
                                    Pole Quantity2 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Functiontrip w/separate reset 
- 
                                    Auxiliary Switch Function And Quantity1 control 
- 
                                    Adjustable Trip Setting Current Range Per Pole In Amps+800.0/+1600.0 dc all locations 
- 
                                    Reset Methodmanual 
- 
                                    Features Providedadjustable trip release 
- 
                                    Trip Release Characteristicinstantaneous all locations and time delay all locations 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Mounting Facility Type And Quantity8 threaded hole 
- 
                                    Overall Length25.000 inches nominal 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Manual Actuator Type And Quantity1 push-pull and 1 rotary 
- 
                                    Nondefinitive Spec/Std Dataacb type 
- 
                                    Case Materialmetal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts250.0 dc all locations 
- 
                                    Overall Width24.000 inches nominal 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps60000.0 dc all locations 
- 
                                    Terminal Type And Quantity4 bus bar 
- 
                                    Reference Number Differentiating Characteristicsas differentiated by pole quantity,maximum continuous loadcurrent rating per pole,tripping time in seconds 
- 
                                    Maximum Continuous Load Current Rating Per Pole800.0 amperes dc all locations 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    