NSN: 5925-00-547-7739

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Mounting Surface To Terminal End Distance

    2.000 inches minimum and 2.031 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

  • Boss Height

    0.099 inches minimum and 0.161 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Specification/standard Data

    81349-mil-c-55629/5 government specification

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.629 inches minimum and 1.691 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 9.450 maximum at 200 pct all locations

  • Case Material

    plastic

  • Body Width

    2.219 inches minimum and 2.281 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Test Data Document

    81349-milc55629/5 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • ~1

    data on certain environmental and performanc

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...