Technical Characteristics
- 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4800.0 dc single location
 - 
                                    
Overall Length
3.156 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Overall Height
1.906 inches nominal
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 - 
                                    
Actuator Function
reset
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof
 - 
                                    
Nominal Thread Size
0.190 inches
 - 
                                    
Reset Method
manual
 - 
                                    
Thread Series Designator
unf
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
 - 
                                    
Precious Material
silver
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
105.0 amperes dc single location
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.406 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 push-pull
 - 
                                    
Pole Quantity
1
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
 - 
                                    
Overall Width
1.875 inches nominal
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    