NSN: 5925-00-581-5841
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
 - 
                                    
Trip Release Method
magnetic-hydraulic
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
 - 
                                    
Boss Height
0.125 inches minimum and 0.135 inches maximum
 - 
                                    
Pole Quantity
1
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Body Style
single pole type
 - 
                                    
Body Width
0.745 inches minimum and 0.755 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
 - 
                                    
Inclosure Protection Type For Which Designed
dustproof and fungus proof
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Body Length
1.985 inches minimum and 2.015 inches maximum
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
2.800 minimum at 200 pct and 25.000 maximum at 200 pct
 - 
                                    
Frequency In Hertz
400.0
 - 
                                    
Terminal Type And Quantity
2 tab,solder lug
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    