NSN: 5925-00-588-8699
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Thread Pitch Diameters
0.3547 to 0.3591 inches
 - 
                                    
Body Length
1.500 inches maximum
 - 
                                    
Body Width
1.875 inches maximum
 - 
                                    
Case Material
metal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
0.620 inches minimum and 0.630 inches maximum
 - 
                                    
Nonturn Device Diameter
0.245 inches minimum and 0.255 inches maximum
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Mounting Surface To Terminal End Distance
1.780 inches maximum
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac first location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc second location
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc third location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac first location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc second location
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac first location
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc third location
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct
 - 
                                    
Frequency In Hertz
400.0 first location
 - 
                                    
Body Style
1b multipole-single actuator type
 - 
                                    
Bushing Length
0.380 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
 - 
                                    
Nonturn Device Location
at 3 oclock and at 9 oclock
 - 
                                    
Nonturn Device Radius
0.620 inches minimum and 0.630 inches maximum
 - 
                                    
Nonturn Device Length
0.135 inches minimum and 0.145 inches maximum
 - 
                                    
Pole Quantity
3
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc second location
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Inclosure Protection Type For Which Designed
hermetically sealed
 - 
                                    
Terminal Type And Quantity
6 wire hook
 - 
                                    
Thread Series Designator
unef
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    