NSN: 5925-00-615-7702

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.974 inches minimum and 0.994 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Nominal Thread Size

    0.164 inches

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Body Width

    2.990 inches minimum and 3.010 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and 0.994 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...