NSN: 5925-00-622-0345
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Switch Terminal Type
tab, solder lug
 - 
                                    
Body Style
rectangular dimensional envelope
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Overall Height
1.168 inches minimum and 1.232 inches maximum
 - 
                                    
Overall Width
1.968 inches minimum and 2.032 inches maximum
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac single location
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Terminal Type And Quantity
2 tab, solder lug
 - 
                                    
Overall Length
4.636 inches minimum and 4.700 inches maximum
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct single location and 1.500 maximum at 200 pct single location
 - 
                                    
Trip Release Method
magnetic-hydraulic single location
 - 
                                    
Mounting Facility Type And Quantity
2 terminal
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Auxiliary Switch Function And Quantity
1 alarm
 - 
                                    
Unpackaged Unit Weight
2.500 ounces
 - 
                                    
Switch Location And Position Designation
internal at pole one
 - 
                                    
Case Material
plastic
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
 - 
                                    
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Switch Contact Arrangement
single pole, double throw
 - 
                                    
Pole Quantity
1
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    