NSN: 5925-00-655-3892
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.735 inches minimum and 2.765 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Body Width
3.016 inches minimum and 3.046 inches maximum
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
416.0 ac all locations
 - 
                                    
Actuator Position Designation
at each pole
 - 
                                    
Reset Method
manual
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Characteristic
time delay all locations
 - 
                                    
Boss Height
0.151 inches minimum and 0.161 inches maximum
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
External Actuator Linkage Arrangement
one, two, and three linked
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Body Style
multipole-multiple actuator type
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and 1.046 inches maximum
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
 - 
                                    
Mounting Facility Type And Quantity
6 threaded hole
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and 1.046 inches maximum
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
70.000 nominal all locations
 - 
                                    
Body Length
3.703 inches minimum and 3.733 inches maximum
 - 
                                    
Frequency In Hertz
400.0 all locations
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations
 - 
                                    
Manual Actuator Type And Quantity
3 toggle
 - 
                                    
Mounting Surface To Terminal End Distance
2.594 inches minimum and 2.624 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
3.047 inches minimum and 3.077 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations and 30.000 maximum at 200 pct all locations
 - 
                                    
Terminal Type And Quantity
6 threaded stud
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    