NSN: 5925-00-679-1308
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Reset Method
manual
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
5.125 inches nominal
 - 
                                    
Terminal Type And Quantity
4 compression
 - 
                                    
Boss Height
0.250 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations and 70.0 amperes dc all locations
 - 
                                    
Body Height
3.594 inches nominal
 - 
                                    
Body Width
3.000 inches nominal
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Unthreaded Mounting Hole Diameter
0.164 inches nominal
 - 
                                    
Actuator Position Designation
between pole one and two
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.594 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 ac all locations and 5000.0 dc all locations
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 250.0 dc all locations
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    


