NSN: 5925-00-690-0249
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Bushing Length
0.375 inches nominal
 - 
                                    
Body Width
0.598 inches nominal
 - 
                                    
Mounting Surface To Terminal End Distance
1.555 inches nominal
 - 
                                    
Pole Quantity
1
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
250.0 milliamperes ac
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Method
magnetic-hydraulic
 - 
                                    
Trip Release Characteristic
time delay
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Ultimate Trip Time Per Pole In Seconds
0.650 minimum and 4.000 maximum
 - 
                                    
Reset Method
manual
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Unpackaged Unit Weight
2.100 ounces
 - 
                                    
Terminal Type And Quantity
2 wire hook
 - 
                                    
Body Length
1.479 inches nominal
 - 
                                    
Case Material
metal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
1 threaded bushing
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac
 - 
                                    
Internal Trip Release Configuration
series trip
 - 
                                    
Nominal Thread Size
0.375 inches
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct and 0.550 maximum at 200 pct
 - 
                                    
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and hermetically sealed
 - 
                                    
Test Data Document
84955-ks10404 drawing
 - 
                                    
Thread Series Designator
unef
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    