Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.021 inches minimum and 1.041 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    3.5 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Center To Center Distance Between Terminals Parallel To Width

    1.021 inches minimum and 1.041 inches maximum

  • Unpackaged Unit Weight

    1.770 pounds

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Surface To Terminal End Distance

    3.177 inches minimum and 3.301 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Width

    3.042 inches minimum and 3.062 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Frequency In Hertz

    60.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...