Technical Characteristics
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current60.000 nominal at 150 pct single location and 20.000 nominal at 200 pct single location 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Body Height2.312 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal single location 
- 
                                    Terminal Type And Quantity1 clip and 1 compression 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Inclosure Protection Type For Which Designedfungus resistant 
- 
                                    Pole Quantity1 
- 
                                    Boss Height0.250 inches nominal 
- 
                                    Body Length3.000 inches nominal 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Trip Release Methodthermal-magnetic single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 single location 
- 
                                    Body Width0.734 inches nominal 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes ac single location 
- 
                                    Body Stylesingle pole type 
- 
                                    Mounting Facility Type And Quantity2 terminal 
- 
                                    Frequency In Hertz60.0 single location 
- 
                                    Trip Release Characteristicinstantaneous single location and time delay single location 
- 
                                    Case Materialplastic 
- 
                                    Fragility Factormoderately rugged 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac single location 