NSN: 5925-00-881-9765

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    10 wire hook

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes dc first location

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes dc second location

  • Body Width

    1.562 inches maximum

  • Thread Series Designator

    unef

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac third location

  • Body Length

    1.937 inches maximum

  • Bushing Length

    0.330 inches nominal

  • Internal Trip Release Configuration

    relay trip first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.280 nominal at 150 pct all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.500 nominal all locations

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Internal Trip Release Configuration

    relay trip second location

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...