NSN: 5925-00-882-3626

Technical Characteristics

  • Auxiliary Switch Function And Quantity

    1 control

  • Mounting Surface To Terminal End Distance

    1.420 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Center To Center Distance Between Terminals Parallel To Length

    0.593 inches nominal

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Bushing Length

    0.359 inches nominal

  • Trip Release Method

    thermal single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Pole Quantity

    1

  • Case Material

    metal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    explosion resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    external at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Body Width

    0.580 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Specification/standard Data

    96906-ms26574 government standard

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Length

    0.780 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Switch Current Rating And Type In Amps

    1.0 ac and 1.0 dc

  • Switch Terminal Type

    tab, solder lug

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...