NSN: 5925-00-896-3113
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Mounting Facility Type And Quantity
6 threaded hole
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 2000.0 dc all locations
-
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
-
Unpackaged Unit Weight
0.875 pounds
-
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Switch Contact Arrangement
single pole, double throw
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic all locations
-
Thread Quantity Per Inch
32
-
Internal Trip Release Configuration
series trip all locations
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.047 inches minimum and 2.077 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
-
Storage Type
general purpose warehouse
-
Reset Method
manual
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
-
Terminal Type And Quantity
6 threaded stud
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations and 5.0 amperes dc all locations
-
Case Material
plastic
-
Manual Actuator Type And Quantity
3 toggle
-
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant and salt spray proof
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Width
2.230 inches minimum and 2.485 inches maximum
-
Switch Location And Position Designation
internal at each pole
-
Arc Quenching Method
magnetic blowout
-
Boss Height
0.125 inches minimum and 0.155 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Frequency In Hertz
60.0 all locations
-
Body Length
2.485 inches minimum and 2.515 inches maximum
-
Nominal Thread Size
0.138 inches
-
Mounting Surface To Terminal End Distance
2.650 inches minimum and 2.800 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations
Related Parts by Category
Related Manufacturers


AS6081 Methods