NSN: 5925-00-927-6703
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Length3.000 inches nominal 
- 
                                    Boss Height0.187 inches nominal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac single location 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps10000.0 ac single location 
- 
                                    Trip Release Methodthermal-magnetic single location 
- 
                                    Trip Release Characteristictime delay single location 
- 
                                    Reset Methodmanual 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Actuator Position Designationat pole one 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current9.000 minimum at 200 pct and 60.000 maximum at 200 pct single location 
- 
                                    Inclosure Protection Type For Which Designedgeneral purpose 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal single location 
- 
                                    Terminal Type And Quantity1 clip and 1 compression 
- 
                                    Body Style10a single pole type 
- 
                                    Body Width1.000 inches nominal 
- 
                                    Body Height3.000 inches nominal 
- 
                                    Case Materialplastic 
- 
                                    Pole Quantity1 
- 
                                    Mounting Facility Type And Quantity2 terminal 
- 
                                    Maximum Continuous Load Current Rating Per Pole50.0 amperes ac single location 
- 
                                    Circuit Protection Typeovercurrent single location 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 
- 
                                    Frequency In Hertz60.0 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    