NSN: 5925-00-984-2798
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Unpackaged Unit Weight
0.280 pounds
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Method
magnetic single location
 - 
                                    
Special Handling Feature
magnetic
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Actuator Function
trip w/separate reset
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Precious Material
silver
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Body Width
0.740 inches minimum and 0.760 inches maximum
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location
 - 
                                    
Mounting Surface To Terminal End Distance
2.408 inches minimum and 2.552 inches maximum
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
 - 
                                    
Body Length
2.500 inches minimum and 2.530 inches maximum
 - 
                                    
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
 - 
                                    
Pole Quantity
1
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Precious Material And Location
terminals silver and nuts silver and washers silver
 - 
                                    
Body Style
single pole type
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location
 - 
                                    
Frequency In Hertz
60.0 single location
 - 
                                    
Boss Height
0.130 inches minimum and 0.150 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    