NSN: 5925-01-021-3784

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Center To Center Distance Between Terminals Parallel To Length

    0.850 inches nominal

  • Unpackaged Unit Weight

    1.500 ounces

  • Manual Actuator Type And Quantity

    1 push button

  • Body Width

    0.660 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.375 inches nominal

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Mounting Surface To Terminal End Distance

    1.815 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 45.000 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unef

  • Bushing Length

    0.500 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Quantity Per Inch

    28

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...