NSN: 5925-01-026-9650
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Body Style11b multipole-single actuator type 
- 
                                    Body Length6.990 inches minimum and 
- 
                                    Body Width4.510 inches maximum 
- 
                                    Body Height2.677 inches minimum and 
- 
                                    Center To Center Distance Between Terminals Parallel To Length6.115 inches minimum and 
- 
                                    Center To Center Distance Between Terminals Parallel To Length6.135 inches maximum 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.510 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.369 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.490 inches minimum and 
- 
                                    Iii Fragility Factormoderately rugged 
- 
                                    Boss Height0.208 inches minimum and 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
- 
                                    Maximum Continuous Load Current Rating Per Pole115.0 amperes ac all locations 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps10000.0 ac all locations 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Reset Methodmanual 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.200 minimum at 200 pct and 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.800 maximum at 200 pct all locations 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Terminal Type And Quantity6 compression 
- 
                                    Body Length7.010 inches maximum 
- 
                                    Body Width4.490 inches minimum and 
- 
                                    Body Height2.697 inches maximum 
- 
                                    Case Materialplastic 
- 
                                    Center To Center Distance Between Terminals Parallel To Width1.490 inches minimum and 
- 
                                    Unthreaded Mounting Hole Diameter0.250 inches nominal 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length4.349 inches minimum and 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width1.510 inches maximum 
- 
                                    Iii End Item Identificationgeneral application electronics (gen-ap-e) 
- 
                                    Boss Height0.228 inches maximum 
- 
                                    Pole Quantity3 
- 
                                    Iii Arc Quenching Methodmagnetic blowout 
- 
                                    Iii Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Inclosure Protection Type For Which Designeddustproof 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    