NSN: 5925-01-039-5646

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    40.0 dc third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac and 5000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip first location

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    shunt trip third location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Pole Quantity

    3

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches minimum and 1.058 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Case Material

    plastic

  • Body Width

    3.046 inches minimum and 3.110 inches maximum

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Mounting Slot Width

    0.164 inches nominal

  • Body Style

    8c multipole-multiple actuator type

  • Mounting Surface To Terminal End Distance

    3.172 inches minimum and 3.296 inches maximum

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac first location

  • Boss Height

    0.187 inches minimum and 0.251 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Frequency In Hertz

    60.0

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct and 19.000 maximum at 200 pct all locations

  • Switch Location And Position Designation

    internal at pole two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at each pole

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Trip Release Method

    magnetic-hydraulic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc second location

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes dc third location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...