NSN: 5925-01-044-2306
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Body Length
10.125 inches nominal
 - 
                                    
Body Height
3.812 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
2.750 inches nominal
 - 
                                    
Unthreaded Mounting Hole Diameter
0.190 inches nominal
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Pole Quantity
3
 - 
                                    
Features Provided
adjustable trip release
 - 
                                    
Cubic Measure
465.093 cubic inches
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
400.0 amperes ac
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac
 - 
                                    
Circuit Protection Type
overcurrent
 - 
                                    
Trip Release Characteristic
instantaneous
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
 - 
                                    
Reset Method
manual
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Frequency In Hertz
60.0
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Body Width
8.240 inches minimum and 8.250 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
7.750 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.750 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
 - 
                                    
Boss Height
0.187 inches nominal
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac
 - 
                                    
Trip Release Method
thermal-magnetic
 - 
                                    
Adjustable Trip Setting Current Range Per Pole In Amps
p1200.0/p4000.0 ac
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal
 - 
                                    
Special Features
two line shields to be included with each breaker
 - 
                                    
Proprietary Characteristics
pacs
 - 
                                    
Terminal Type And Quantity
6 compression
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    