NSN: 5925-01-050-8195

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    2.469 inches minimum and 2.531 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.906 inches minimum and 1.968 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2.0 ac single location

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Packaged Unit Weight

    4.500 ounces

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    vibration resistant and fungus resistant and shock resistant

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Special Handling Feature

    magnetic

  • Switch Terminal Type

    tab, solder lug

  • Mounting Surface To Terminal End Distance

    2.828 inches minimum and 2.952 inches maximum

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Arc Quenching Method

    magnetic blowout

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.031 inches minimum and 2.093 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Boss Height

    0.094 inches minimum and 0.156 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...