NSN: 5925-01-057-3775

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.674 inches minimum and 0.734 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.812 inches maximum

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac single location and 25.0 amperes dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Thread Series Designator

    uns

  • Body Style

    7a single pole type

  • Bushing Length

    0.750 inches maximum

  • Body Length

    2.187 inches maximum

  • Body Width

    0.740 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.807 inches minimum and 1.817 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc

  • Trip Release Method

    thermal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.469 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    400.0 single location

  • Unpackaged Unit Weight

    0.158 pounds

  • Terminal Type And Quantity

    2 tab w/screw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...