NSN: 5925-01-063-4380

Technical Characteristics

  • Body Length

    1.500 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac second location

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    3.600 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct second location and 0.700 maximum at 200 pct second location

  • Body Width

    1.250 inches maximum

  • Thread Series Designator

    unef

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 first location

  • Inclosure Protection Type For Which Designed

    shockproof and hermetically sealed and vibrationproof

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Center To Center Distance Between Terminals Parallel To Width

    0.344 inches minimum and 0.406 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent second location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Frequency In Hertz

    60.0 second location

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Internal Trip Release Configuration

    series trip first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc first location

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Trip Release Characteristic

    instantaneous first location

  • Case Material

    metal

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Circuit Protection Type

    overvoltage first location

  • Trip Release Characteristic

    time delay second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Fragility Factor

    moderately rugged

  • Nonturn Device Diameter

    0.250 inches nominal

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    0.594 inches minimum and 0.656 inches maximum

  • Internal Trip Release Configuration

    relay trip second location

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc first location

  • Terminal Type And Quantity

    5 wire hook

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.