NSN: 5925-01-072-3867

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Body Length

    6.438 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 400 pct all locations and 0.400 maximum at 400 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Body Width

    4.469 inches nominal

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Height

    3.157 inches nominal

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.562 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.188 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Terminal Type And Quantity

    6 screw

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    18000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...