NSN: 5925-01-099-0372

Technical Characteristics

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 clip and 2 compression

  • Body Height

    2.310 inches nominal

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Mounting Facility Type And Quantity

    4 terminal

  • Specification/standard Data

    81348-w-c-375/2 government specification

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Length

    3.000 inches nominal

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • ~1

    data on certain environmental and performance re

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Pole Quantity

    2

  • Body Width

    1.480 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...